Technical Specs
FLOOR and more® power hollow floor system construction

Construction drawing from the official Lindner FLOOR and more® power product page.

FLOOR and more® power is Lindner’s dry hollow floor system for heavy-duty areas. The official product page states that the power panels consist of fibre-reinforced calcium sulphate with an optimised panel mixture, and may optionally be supplied with a steel sheet on the lower side.

Values below are summarised from the official Lindner product page as of 14 November 2026. Many figures are published as ranges and may depend on system configuration or additional measures. Please confirm project-specific performance against the current Lindner data sheet. Items not stated on that page are omitted here.

Technical details
Panel thickness40 – 44.5 mm
Standard pedestal height57 – 2,000 mm
Pedestal grid600 mm × 600 mm
Weight62 – 83 kg/m²
Static
Load classDIN EN 13213, 6
Point load (breaking load)EN 13213, 6 kN (12 kN) – 20 kN (40 kN)
Seismic safetyPossible according to DIN EN 1998-1
Fire protection
Building material class of the carrier panelEN 13501-1, A1 (non-combustible)
Fire resistanceDIN 4102-2, F 30
Fire resistance (with additional measures)EN 13501-2, REI 30 possible; REI 60 possible
Sustainability
Circular economyCradle to Cradle Certified® Silver
Sustainable forestryCan be supplied FSC™-certified (chain of custody). Licence number: FSC™ C119815
EPDEPD according to EN 15804 / ISO 14025 upon request
Product self-declarationSelf-declaration according to ISO 14021 upon request

Suitable coverings stated on the official page include elastic coverings, textile coverings, ceramics, natural stone, and coatings after consultation with Product Management Flooring.

Features
Interior photograph from the official FLOOR and more power product page, AMG Brand Center Essen

Application photograph from the official Lindner FLOOR and more® power product page. Project: AMG Brand Center, Essen.

The following points summarise features stated on Lindner’s official FLOOR and more® power page. They are not a complete specification.

● Dry hollow floor developed for heavy-duty areas

● Fibre-reinforced calcium sulphate panel, optionally with a steel sheet on the lower side

● Single-layer design up to 24 kN point load, as stated on the official product page

● Described as accessible with heavy lifting platforms and vehicles

● No reinforcement profiles necessary, as stated on the official product page

● Very high load capacity with a low base layer thickness

● Carrier panel classified non-combustible, EN 13501-1 A1

● Load class DIN EN 13213, 6

● Cradle to Cradle Certified® Silver

Documentation
FLOOR and more® power hollow floor system construction
More About
A Global Supplier of Hilti Lindner Authorized Dealer